Salient Features of S400D
model on line UPS systems.
1.True On-line
double conversion Technology, The Best Available technology for
guarding mission critical systems. Duel Microprocessor and Digital
Signal Processing ( DSP) based System. Uses IGBTs as basic power
devices. Rugged and Robust design to provide fit and forget reliability.
Power factor correction, even with low power factor load, to >0.99
resulting lower power consumption.
2. Wide input voltage range (+25%, -30%).
This UPS is designed to work on 3Phase power (as 10 KVA load should not
be connected to a single phase) and it can work under wide input voltage
range. The input voltage range is 290V to 518V Phase to phase Voltage.
3. Battery Management, temperature
compensated charging.
4. This UPS supplies Precise Sine Wave power
thus providing protection from all type of disturbances including
Lightning and surges, Voltage sags, Harmonics and power Outages. With
capability to cater 100% non Linear load suitable
for any kind of load.
5. 1+1 Redundant configuration possible
with one more UPS for 100% availability. 2 UPSs can be configured to
work on common battery bank. DG can also be connected to this UPS as an
additional back up source in this configuration.
6. This UPS is designed to work on
3Phase power (as 10 KVA load should not be connected to a single phase)
and it can work under wide input voltage range.
7.Battery management features including Temperature compensated charging
of batteries to protect the batteries.
8. Fault Tolerance. The fail-safe static
bypass ensure the power supply to your critical load even during UPS
over load or fault conditions. In case of a fault the load is
transferred to the stand by (by pass) Power.
9. The servicing of the UPS can be done,
components can be repaired/replaced and restart the systems and transfer
the load to UPS, all are possible without
disturbing the load. Access to the inside components of the UPS
is possible from the front side only and hence the space required for
installation is also less compared to other UPS systems.
10.To ensure safe working of the critical load this UPS can do online
battery test even when the critical load is
on.
11. LCD Display l on the front panel. The
user can read the status of the UPS with readings of all parameters
including voltages current of input/output, Battery, load, back up time,
battery charge etc. from the LCD panel.
12. Data logging and event history. Supper
400 can identify and display 45 fault conditions on its front panel.
Also It can store and display 200 alarm events (input over voltage,
power failure, power restoration, ups on,off etc.). the customer can
find out if there was a power failure last week on one particular day
and what time it happened and what was the load at that time and What
was the out put voltage.
13. Intelligent network interface port. UPS
monitoring is possible with site Net software. All major OS platforms
are supported including windows, UNIX, Novel, HP, DEC and many others.
14. Cold start facility with 100% load
in the absence of utility power.
15. Smallest foot print This Equipment is
constructed zinc-plated steel structure an the front panel is held
in place by a snap fit arrangement. Size (WxDxH) 450x650x1150 (mm).
16. Excellent service backup as we are
specialist in UPS System having 22 years of
experience in UPS maintenance and we extend our maintenance
support to all major organizations in Vidharbha. We are having
Liebert (Emerson) trained engineers for Liebert UPS Systems. These are
in addition to the support from Liebert (Emerson) who is having country
wide service network with India's best available manpower.
All these are in addition to the normal specifications of a
standard UPS system
For further details,
please call us 0712 2438907, 2428319 E-mail
Prices
at Nagpur exclusive of taxes.
10 KVA Rs.275000.00 Suitable for 50 computers with color VDU
20 KVA Rs.375000.00 For 100 computers
|